Press F4 or F9 and scroll to Curr. L. (A), low weld current in amps.
Press F5 or F10 and enter Low current value from 0.2~150 amps.
Press F4 or F9 and scroll to Pulse H. (S), high weld current pulse
time.
Press F5 or F10 and enter High weld current pulse time from
0.00~0.99 seconds.
Press F4 or F9 and scroll to Pulse L. (S), low weld current pulse
time.
Press F5 or F10 and enter Low weld current pulse time from
0.00~0.99 seconds.
Press F4 or F9 and scroll to Pre-Gas (S), pre-purge gas time.
Press F5 or F10 and enter pre-purge gas time from 0.0~9.9 seconds.
Press F4 or F9 and scroll to Post-Gas (S), post-purge gas time.
Press F5 or F10 and enter post-purge gas time from 0.0~9.9
seconds.
Press F4 or F9 and scroll to Strike (A), arc strike weld current.
Press F5 or F10 and enter arc strike weld current from 0.1~25.0
amps.
Press Foot Control to maximum and hold for duration of weld
Press F6 Print Weld wave form graphics from integral printer
WELD MANUAL SCREEN DISPLAY
F1, Start/Stop, used for manual Start/Stop operations without a foot
control.
F2, Main Menu, returns to the Main Menu display.
F3, Weld Orbital, returns to the Weld Orbital display.
F4, Scroll UP, scrolls the highlighted eld from one demand
parameter to the next demand parameter.
F5, Adjust Up, increases the numerical value of the demand
parameter selected. As this button is pressed for each parameter a
vertical bar graph displays the increasing value, both numerically and
graphically from the bar graph. For most parameters, a maximum
value is obtained once the vertical bar graph has reached the top of
the scale. Also, there is a change in the sound once the top of the
scale has been reached. The sound changes from a single beep to a
triple beep.
F6, Print Weld, Data-Monitoring of manual weld produces a graphical
real time wave form of welding amps and arc volts.
F7, Pedal On, selects the variable remote foot control for operation.
F7, Pedal Off, selects the On/Off switch control and permits additional
programming of weld current Upslope time in seconds and Final
Slope weld current time in seconds.
F8, Blank, no function control.
F9, Scroll Down, scrolls the highlighted eld from one demand
parameter to the next demand parameter.
F10, Adjust Down, decreases the numerical value of the demand
parameter selected. As this button is pressed for each parameter a
vertical bar graph displays the decreasing value, both numerically
and graphically from the bar graph. For most parameters, a minimum
value is obtained once the vertical bar graph has reached the bottom