TM 5-4310-452-14
4-22. METERING FUEL PUMP MAINTENANCE.
This Task Covers:
a. Removal c. Assembly
b. Disassembly d. Installation
Initial Setup:
Equipment Conditions: Materials/Parts:
Engine off. Dry cleaning solvent (Item 3, Appendix E)
Left door assembly open. Rag (Item 11, Appendix E)
Left door assembly open. Fuel pump parts kit
Tools/Test Equipment: One gasket
General mechanic's tool kit Three lockwashers
•·Soft bristle brush
General Safety Instructions:
Dry cleaning solvent is flammable and must not be used near open flame. Use only in a well-ventilated area.
4-39