TM 5-4310-452-14
4-57. STORAGE BATTERIES REPLACEMENT (Con't).
a. REMOVAL
1. Loosen 4 clamps (5) on battery terminals (7) and
remove battery cables (6).
2. Remove 4 nuts (1), lockwashers (2), flat washers
(3), hook bolts (10), and 2 battery retainers (4) from
storage batteries (8). Discard lockwashers.
WARNING
Storage batteries are heavy. To
prevent injury, use battery strap to
remove storage batteries.
3. Remove 2 storage batteries (8) from battery trays
(9).
b. INSTALLATION
WARNING
Storage batteries are heavy. To prevent injury, use battery strap to Install storage batteries.
1. Position storage batteries (8) in place on battery trays (9).
2. Install 4 hook bolts (10), flat washers (3), new lockwashers (2), nuts (1), and 2 battery retainers (4) on storage
batteries (8).
3. Install battery cables (6) on battery terminals (7) and tighten clamps (5).
FOLLOW-ON TASKS:
Close right door assembly.
TA505491
4-108